Yksd - Allakaket School
PWSID: AK2300206
This system has no unresolved violations. The most recent violation on record was 2025-04-01.
This system has more violations on record than 93% of water systems in Alaska.
Violation trend: 41.0 per year over the last 5 years, up from 8.8 per year in the previous 5.
System Details
| Population Served | 52 |
| Service Connections | 7 |
| Water Source | Groundwater Under Influence |
| System Type | Non-Transient Non-Community |
| Owner | Local Government |
| Status | Active |
| City | Fairbanks |
| EPA ZIP on File | 99709 |
| Note | School or Daycare |
Areas Served
- Allakaket, Yukon-Koyukuk Census Area
Lead & Copper Testing
| Contaminant | Level | EPA Action Level | Status |
|---|---|---|---|
| Copper (90th percentile) | 2.3400 mg/L | 1.300 mg/L | Exceeds Action Level |
| Lead (90th percentile) | 0.0115 mg/L | 0.015 mg/L | Below Action Level |
| Lead (90th percentile) | 0.0110 mg/L | 0.015 mg/L | Below Action Level |
| Lead (90th percentile) | 0.0023 mg/L | 0.015 mg/L | Below Action Level |
| Lead (90th percentile) | 0.0022 mg/L | 0.015 mg/L | Below Action Level |
| Lead (90th percentile) | 0.0022 mg/L | 0.015 mg/L | Below Action Level |
| Lead (90th percentile) | 0.0007 mg/L | 0.015 mg/L | Below Action Level |
Violation History (262 total)
| Contaminant | Violation | Date | Health-Based | Status |
|---|---|---|---|---|
| 2950 | MCL Measured: 0.1050 MG/L (limit: 0.0800 MG/L) | 2025-04-01 | Yes | Acknowledged |
| 2950 | MCL Measured: 0.1050 MG/L (limit: 0.0800 MG/L) | 2025-04-01 | Yes | Returned to Compliance |
| 2950 | MR | 2025-01-01 | Major | Acknowledged |
| 2950 | MR | 2025-01-01 | Major | Returned to Compliance |
| 2456 | MR | 2025-01-01 | Major | Acknowledged |
| 2456 | MR | 2025-01-01 | Major | Returned to Compliance |
| 2950 | MCL Measured: 0.1160 MG/L (limit: 0.0800 MG/L) | 2025-01-01 | Yes | Acknowledged |
| 2950 | MCL Measured: 0.1160 MG/L (limit: 0.0800 MG/L) | 2025-01-01 | Yes | Returned to Compliance |
| 0200 | MR | 2024-10-01 | Major | Returned to Compliance |
| 0999 | MR | 2024-10-01 | Major | Returned to Compliance |
| 2950 | MCL Measured: 0.1160 MG/L (limit: 0.0800 MG/L) | 2024-10-01 | Yes | Acknowledged |
| 2950 | MCL Measured: 0.1160 MG/L (limit: 0.0800 MG/L) | 2024-10-01 | Yes | Returned to Compliance |
| 0300 | MR | 2024-10-01 | Major | Returned to Compliance |
| 0999 | MR | 2024-09-01 | Major | Returned to Compliance |
| 0999 | MR | 2024-09-01 | Major | Acknowledged |
| 0999 | MR | 2024-09-01 | Major | Returned to Compliance |
| 0200 | MR | 2024-09-01 | Major | Returned to Compliance |
| 0200 | MR | 2024-09-01 | Major | Acknowledged |
| 0200 | MR | 2024-09-01 | Major | Returned to Compliance |
| 0200 | MR | 2024-08-01 | Major | Returned to Compliance |
| 0200 | MR | 2024-08-01 | Major | Acknowledged |
| 0200 | MR | 2024-08-01 | Major | Returned to Compliance |
| 8000 | MON | 2024-08-01 | Major | Returned to Compliance |
| 8000 | MON | 2024-08-01 | Major | Acknowledged |
| 8000 | MON | 2024-08-01 | Major | Returned to Compliance |
| 0999 | MR | 2024-08-01 | Major | Returned to Compliance |
| 0999 | MR | 2024-08-01 | Major | Acknowledged |
| 0999 | MR | 2024-08-01 | Major | Returned to Compliance |
| 2950 | MCL Measured: 0.1340 MG/L (limit: 0.0800 MG/L) | 2024-07-01 | Yes | Returned to Compliance |
| 2950 | MCL Measured: 0.1340 MG/L (limit: 0.0800 MG/L) | 2024-07-01 | Yes | Acknowledged |
| 0999 | MR | 2024-04-01 | Major | Returned to Compliance |
| 0999 | MR | 2024-04-01 | Major | Returned to Compliance |
| 0200 | MR | 2024-04-01 | Major | Returned to Compliance |
| 0200 | MR | 2024-04-01 | Major | Returned to Compliance |
| 8000 | MON | 2024-04-01 | Major | Returned to Compliance |
| 8000 | MON | 2024-04-01 | Major | Returned to Compliance |
| 2950 | MR | 2024-04-01 | Major | Returned to Compliance |
| 2950 | MR | 2024-04-01 | Major | Acknowledged |
| 2950 | MR | 2024-04-01 | Major | Returned to Compliance |
| 2456 | MR | 2024-04-01 | Major | Returned to Compliance |
| 2456 | MR | 2024-04-01 | Major | Acknowledged |
| 2456 | MR | 2024-04-01 | Major | Returned to Compliance |
| 8000 | MON | 2024-03-01 | Major | Returned to Compliance |
| 8000 | MON | 2024-03-01 | Major | Acknowledged |
| 8000 | MON | 2024-03-01 | Major | Returned to Compliance |
| 0200 | MR | 2024-03-01 | Major | Returned to Compliance |
| 0200 | MR | 2024-03-01 | Major | Returned to Compliance |
| 0200 | MR | 2024-03-01 | Major | Acknowledged |
| 0200 | MR | 2024-02-01 | Major | Returned to Compliance |
| 0200 | MR | 2024-02-01 | Major | Acknowledged |
Showing 50 of 262 historical violations.
Understanding This Water System's Record
Yksd - Allakaket School is a non-transient non-community water system that draws from groundwater under influence sources and serves a population of 52 in Fairbanks, Alaska. This page shows its complete compliance history as reported to the EPA's Safe Drinking Water Information System (SDWIS), the federal database that tracks every public water system in the United States.
What Do These Violations Mean?
Health-based violations mean the system exceeded an EPA maximum contaminant level (MCL) or failed to provide required treatment. These indicate potential health risks from contaminants like lead, arsenic, bacteria, nitrates, or disinfection byproducts. Non-health-based violations involve monitoring, reporting, or procedural requirements — the system missed a testing deadline or failed to notify customers, but contaminant levels were not necessarily unsafe.
What Should You Do?
Your water utility is required to publish an annual Consumer Confidence Report (CCR) that details test results and any violations. If your system has active health-based violations, consider a certified water filter rated for the specific contaminants involved. The contaminant guides on this site explain health risks and filter options for common pollutants. For the most current results, contact your water utility directly — EPA data can lag weeks or months behind real-time testing.