Ranch Water Service Inc
A missed test is not evidence of bad water. It also is not evidence of good water: for that period nobody checked.
On record since 2002: 259 violations. 72 over the limit · 1 treatment lapse · 139 missed or late tests · 47 notices or reports. Most recent began 2025-07-01.
For this year's test results, ask the utility for its annual Consumer Confidence Report. Every community system must publish one.
More violations on record than 99% of active water systems in Arizona. Small systems with no staff chemist often rack up missed-test violations; big utilities rarely do.
The record, year by year
Across Arizona, 65% of violations are missed or late tests and 5% are water over a limit.
How far over the limit
Lead & copper at the tap
Utilities sample taps in homes most likely to have lead pipes, and report the 90th-percentile result: 9 in 10 homes sampled came in at or below this number. Above the red line (the action level) the utility must act. The action level is not a safe level; EPA's health goal for lead is zero. EPA's file does not date these results, so they are shown highest first.
Lead, 90th percentile 4 results on file · action level 15 ppb
Open now (2)
- 2025-07-01Consumer Confidence RuleCCR Complete Failure to ReportOpen
- 2019-10-02Consumer Confidence RuleCCR Inadequate ReportingOpen
Every violation on record
- 2025-07-01Consumer Confidence RuleCCR Complete Failure to ReportOpen
- 2025-04-01ArsenicMonitoring, RegularPeriod ended · no return to compliance on file
- 2025-04-01Combined Radium (-226 and -228)Monitoring, RegularPeriod ended · no return to compliance on file
- 2025-04-01Combined UraniumMonitoring, RegularPeriod ended · no return to compliance on file
- 2025-04-01Revised Total Coliform RuleMONBack in compliance
- 2024-12-20Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2024-10-17Lead service line inventoryRPTBack in compliance
- 2024-10-17Lead service line inventoryTTBack in compliance
- 2024-10-02Consumer Confidence RuleCCR Inadequate ReportingBack in compliance
- 2024-09-01Revised Total Coliform RuleMONBack in compliance
- 2024-07-01ArsenicMonitoring, RegularBack in compliance
- 2024-07-01Combined UraniumMonitoring, RegularBack in compliance
- 2024-07-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2024-07-01Consumer Confidence RuleCCR Complete Failure to ReportBack in compliance
- 2024-06-02Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2024-05-02Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2024-04-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2024-04-01Combined UraniumMonitoring, RegularBack in compliance
- 2024-04-01Revised Total Coliform RuleMONBack in compliance
- 2024-01-01Lead and Copper RuleLead Consumer NoticeBack in compliance
- 2023-11-25Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2023-11-02Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2023-11-01Revised Total Coliform RuleMONBack in compliance
- 2023-10-02Consumer Confidence RuleCCR Inadequate ReportingBack in compliance
- 2023-10-01ArsenicMonitoring, RegularBack in compliance
Show the other 233 entries
- 2023-10-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2023-10-01Combined UraniumMonitoring, RegularBack in compliance
- 2023-10-01Lead and Copper RuleFollow-up Or Routine LCR Tap M/RBack in compliance
- 2023-09-01Revised Total Coliform RuleMONBack in compliance
- 2023-07-20Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2023-07-02Public Notice ×2PN Violation for NPDWR ViolationBack in compliance
- 2023-07-01Revised Total Coliform RuleRPTBack in compliance
- 2023-06-24Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2023-05-01Revised Total Coliform RuleMONBack in compliance
- 2023-04-02Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2023-04-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2023-04-01Combined UraniumMonitoring, RegularBack in compliance
- 2023-04-01Revised Total Coliform RuleMONBack in compliance
- 2023-03-02Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2023-02-12Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2023-01-02Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2022-12-04Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2022-12-02Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2022-11-01Revised Total Coliform RuleMONBack in compliance
- 2022-10-02Consumer Confidence RuleCCR Inadequate ReportingBack in compliance
- 2022-10-01Combined UraniumMonitoring, RegularBack in compliance
- 2022-10-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2022-10-01ArsenicMonitoring, RegularBack in compliance
- 2022-10-01Revised Total Coliform RuleMONBack in compliance
- 2022-08-26Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2022-08-01Revised Total Coliform RuleRPTBack in compliance
- 2022-07-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2022-07-01Combined UraniumMonitoring, RegularBack in compliance
- 2022-06-02Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2022-05-01Revised Total Coliform RuleMONBack in compliance
- 2022-04-01Combined UraniumMonitoring, RegularBack in compliance
- 2022-04-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2022-04-01ArsenicMonitoring, RegularBack in compliance
- 2022-03-12Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2022-03-01Revised Total Coliform RuleMONBack in compliance
- 2022-02-01Revised Total Coliform RuleMONBack in compliance
- 2022-01-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2022-01-01ArsenicMonitoring, RegularBack in compliance
- 2022-01-01Combined UraniumMonitoring, RegularBack in compliance
- 2021-12-12Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2021-12-01Revised Total Coliform RuleMONBack in compliance
- 2021-11-01Revised Total Coliform RuleMONBack in compliance
- 2021-10-02Consumer Confidence RuleCCR Inadequate ReportingBack in compliance
- 2021-10-01ArsenicMonitoring, RegularBack in compliance
- 2021-10-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2021-10-01Combined UraniumMonitoring, RegularBack in compliance
- 2021-07-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2021-07-01Combined UraniumMonitoring, RegularBack in compliance
- 2021-07-01ArsenicMonitoring, RegularBack in compliance
- 2021-07-01Revised Total Coliform RuleMONBack in compliance
- 2021-07-01Consumer Confidence RuleCCR Complete Failure to ReportBack in compliance
- 2021-05-01Revised Total Coliform RuleMONBack in compliance
- 2021-03-01Revised Total Coliform RuleRPTBack in compliance
- 2021-02-01Revised Total Coliform RuleMONBack in compliance
- 2021-01-02Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2021-01-01ArsenicMonitoring, RegularBack in compliance
- 2021-01-01Combined UraniumMonitoring, RegularBack in compliance
- 2021-01-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2021-01-01Lead and Copper RuleLead Consumer NoticeBack in compliance
- 2020-11-01Revised Total Coliform RuleMONBack in compliance
- 2020-10-02Consumer Confidence RuleCCR Inadequate ReportingBack in compliance
- 2020-10-01ArsenicMonitoring, RegularBack in compliance
- 2020-10-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2020-10-01Combined UraniumMonitoring, RegularBack in compliance
- 2020-10-01Lead and Copper RuleFollow-up Or Routine LCR Tap M/RBack in compliance
- 2020-07-01ArsenicMonitoring, RegularBack in compliance
- 2020-07-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2020-07-01Combined UraniumMonitoring, RegularBack in compliance
- 2020-07-01Consumer Confidence RuleCCR Complete Failure to ReportBack in compliance
- 2020-05-01Revised Total Coliform RuleRPTBack in compliance
- 2020-04-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2020-04-01Combined UraniumMonitoring, RegularBack in compliance
- 2020-04-01ArsenicMonitoring, RegularBack in compliance
- 2019-12-01Revised Total Coliform RuleMONBack in compliance
- 2019-10-02Consumer Confidence RuleCCR Inadequate ReportingOpen
- 2019-07-01Combined UraniumMonitoring, RegularBack in compliance
- 2019-07-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2019-07-01ArsenicMonitoring, RegularBack in compliance
- 2019-07-01Revised Total Coliform RuleRPTBack in compliance
- 2019-07-01Consumer Confidence RuleCCR Complete Failure to ReportBack in compliance
- 2019-04-01ArsenicMonitoring, RegularBack in compliance
- 2019-04-01Radium-228Monitoring, RegularBack in compliance
- 2019-04-01Radium-226Monitoring, RegularBack in compliance
- 2019-04-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2019-04-01Combined UraniumMonitoring, RegularBack in compliance
- 2019-04-01Gross Alpha, Excl. Radon and UMonitoring, RegularBack in compliance
- 2018-10-01ArsenicMonitoring, RegularBack in compliance
- 2018-10-01Radium-228Monitoring, RegularBack in compliance
- 2018-10-01Radium-226Monitoring, RegularBack in compliance
- 2018-10-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2018-10-01Combined UraniumMonitoring, RegularBack in compliance
- 2018-10-01Gross Alpha, Excl. Radon and UMonitoring, RegularBack in compliance
- 2018-08-01Revised Total Coliform RuleRPTBack in compliance
- 2018-03-01Revised Total Coliform RuleRPTBack in compliance
- 2018-01-01Radium-228Monitoring, RegularBack in compliance
- 2018-01-01Radium-226Monitoring, RegularBack in compliance
- 2018-01-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2018-01-01Combined UraniumMonitoring, RegularBack in compliance
- 2018-01-01Gross Alpha, Excl. Radon and UMonitoring, RegularBack in compliance
- 2018-01-01ArsenicMonitoring, RegularBack in compliance
- 2018-01-01ChlorineMonitoring and Reporting (DBP)Back in compliance
- 2017-11-03Lead and Copper RuleLead Consumer NoticeBack in compliance
- 2017-10-01Radium-228MCL, Single Samplemeasured 11.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2017-10-01Combined Radium (-226 and -228)MCL, Single Samplemeasured 13.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2017-10-01Combined UraniumMCL, Single Samplemeasured 34.00 UG/L · limit 30.00 UG/LBack in compliance
- 2017-10-01Radium-228Monitoring, RegularBack in compliance
- 2017-10-01Radium-226Monitoring, RegularBack in compliance
- 2017-10-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2017-10-01Combined UraniumMonitoring, RegularBack in compliance
- 2017-10-01Gross Alpha, Excl. Radon and UMonitoring, RegularBack in compliance
- 2017-10-01ArsenicMonitoring, RegularBack in compliance
- 2017-10-01ChlorineMonitoring and Reporting (DBP)Back in compliance
- 2017-08-01Revised Total Coliform RuleMONBack in compliance
- 2017-07-01Radium-228MCL, Averagemeasured 10.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2017-07-01Combined Radium (-226 and -228)MCL, Averagemeasured 13.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2017-07-01Combined UraniumMCL, Averagemeasured 32.00 UG/L · limit 30.00 UG/LBack in compliance
- 2017-07-01ChlorineMonitoring and Reporting (DBP)Back in compliance
- 2017-07-01Radium-228Monitoring, RegularBack in compliance
- 2017-07-01Radium-226Monitoring, RegularBack in compliance
- 2017-07-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2017-07-01Combined UraniumMonitoring, RegularBack in compliance
- 2017-07-01Gross Alpha, Excl. Radon and UMonitoring, RegularBack in compliance
- 2017-07-01Radium-228MCL, Single Samplemeasured 9.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2017-07-01Combined Radium (-226 and -228)MCL, Single Samplemeasured 12.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2017-07-01Combined UraniumMCL, Single Samplemeasured 31.00 UG/L · limit 30.00 UG/LBack in compliance
- 2017-04-01Radium-228Monitoring, RegularBack in compliance
- 2017-04-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2017-04-01Radium-226Monitoring, RegularBack in compliance
- 2017-04-01Combined UraniumMonitoring, RegularBack in compliance
- 2017-04-01Radium-228MCL, Averagemeasured 10.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2017-04-01Combined Radium (-226 and -228)MCL, Averagemeasured 12.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2017-04-01Combined UraniumMCL, Averagemeasured 31.00 UG/L · limit 30.00 UG/LBack in compliance
- 2017-04-01ArsenicMonitoring, RegularBack in compliance
- 2017-04-01ChlorineMonitoring and Reporting (DBP)Back in compliance
- 2017-01-27Revised Total Coliform RuleOtherBack in compliance
- 2017-01-01Radium-228MCL, Averagemeasured 10.00 PCI/LBack in compliance
- 2017-01-01Combined UraniumMCL, Averagemeasured 37.00 UG/L · limit 30.00 UG/LBack in compliance
- 2017-01-01Combined Radium (-226 and -228)MCL, Averagemeasured 12.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2017-01-01ArsenicMonitoring, RegularBack in compliance
- 2017-01-01Radium-228Monitoring, RegularBack in compliance
- 2017-01-01Radium-226Monitoring, RegularBack in compliance
- 2017-01-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2017-01-01Combined UraniumMonitoring, RegularBack in compliance
- 2017-01-01Gross Alpha, Excl. Radon and UMonitoring, RegularBack in compliance
- 2017-01-01ChlorineMonitoring and Reporting (DBP)Back in compliance
- 2016-10-01ChlorineMonitoring and Reporting (DBP)Back in compliance
- 2016-10-01Radium-228Monitoring, RegularBack in compliance
- 2016-10-01Radium-226Monitoring, RegularBack in compliance
- 2016-10-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2016-10-01Combined UraniumMonitoring, RegularBack in compliance
- 2016-10-01Gross Alpha, Excl. Radon and UMonitoring, RegularBack in compliance
- 2016-10-01Radium-228MCL, Averagemeasured 11.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2016-10-01Combined Radium (-226 and -228)MCL, Averagemeasured 13.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2016-10-01Combined UraniumMCL, Averagemeasured 40.00 UG/L · limit 30.00 UG/LBack in compliance
- 2016-07-01ChlorineMonitoring and Reporting (DBP)Back in compliance
- 2016-07-01Radium-228MCL, Averagemeasured 12.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2016-07-01Combined Radium (-226 and -228)MCL, Averagemeasured 14.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2016-07-01Radium-228Monitoring, RegularBack in compliance
- 2016-07-01Radium-226Monitoring, RegularBack in compliance
- 2016-07-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2016-07-01Combined UraniumMonitoring, RegularBack in compliance
- 2016-07-01Gross Alpha, Excl. Radon and UMonitoring, RegularBack in compliance
- 2016-04-01ChlorineMonitoring and Reporting (DBP)Back in compliance
- 2016-04-01ArsenicMonitoring, RegularBack in compliance
- 2016-04-01Radium-228MCL, Averagemeasured 13.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2016-04-01Combined Radium (-226 and -228)MCL, Averagemeasured 15.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2016-01-01ChlorineMonitoring and Reporting (DBP)Back in compliance
- 2016-01-01ArsenicMonitoring, RegularBack in compliance
- 2016-01-01Radium-228MCL, Averagemeasured 13.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2016-01-01Combined Radium (-226 and -228)MCL, Averagemeasured 15.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2016-01-01Radium-228Monitoring, RegularBack in compliance
- 2016-01-01Radium-226Monitoring, RegularBack in compliance
- 2016-01-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2016-01-01Combined UraniumMonitoring, RegularBack in compliance
- 2016-01-01Gross Alpha, Excl. Radon and UMonitoring, RegularBack in compliance
- 2015-10-01ChlorineMonitoring and Reporting (DBP)Back in compliance
- 2015-10-01Radium-228MCL, Averagemeasured 11.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2015-10-01Combined Radium (-226 and -228)MCL, Averagemeasured 13.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2015-07-01Radium-228MCL, Averagemeasured 11.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2015-07-01Combined Radium (-226 and -228)MCL, Averagemeasured 13.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2015-04-01Radium-228MCL, Averagemeasured 11.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2015-04-01Combined Radium (-226 and -228)MCL, Averagemeasured 13.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2015-04-01Combined UraniumMCL, Averagemeasured 31.00 UG/L · limit 30.00 UG/LBack in compliance
- 2015-01-01Radium-228MCL, Averagemeasured 10.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2015-01-01Combined Radium (-226 and -228)MCL, Averagemeasured 13.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2014-10-01Radium-228MCL, Averagemeasured 9.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2014-10-01Combined Radium (-226 and -228)MCL, Averagemeasured 14.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2014-10-01Combined UraniumMCL, Averagemeasured 32.00 UG/L · limit 30.00 UG/LBack in compliance
- 2014-07-01Radium-228MCL, Averagemeasured 11.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2014-07-01Combined Radium (-226 and -228)MCL, Averagemeasured 17.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2014-07-01Combined UraniumMCL, Averagemeasured 33.00 UG/L · limit 30.00 UG/LBack in compliance
- 2014-04-01Radium-228MCL, Averagemeasured 11.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2014-04-01Combined Radium (-226 and -228)MCL, Averagemeasured 13.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2014-01-01Radium-228MCL, Averagemeasured 11.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2014-01-01Combined Radium (-226 and -228)MCL, Averagemeasured 13.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2013-10-01Combined Radium (-226 and -228)MCL, Averagemeasured 20.60 PCI/L · limit 5.00 PCI/LBack in compliance
- 2013-10-01Radium-228MCL, Averagemeasured 17.10 PCI/L · limit 5.00 PCI/LBack in compliance
- 2013-07-01Radium-228MCL, Averagemeasured 12.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2013-07-01Combined Radium (-226 and -228)MCL, Averagemeasured 13.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2013-04-01Combined Radium (-226 and -228)MCL, Averagemeasured 14.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2013-04-01Radium-228MCL, Averagemeasured 12.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2013-01-01Radium-228MCL, Averagemeasured 10.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2013-01-01Combined Radium (-226 and -228)MCL, Averagemeasured 11.60 PCI/L · limit 5.00 PCI/LBack in compliance
- 2013-01-01Combined UraniumMCL, Averagemeasured 38.20 UG/L · limit 30.00 UG/LBack in compliance
- 2012-10-01Combined UraniumMCL, Averagemeasured 33.00 UG/L · limit 30.00 UG/LBack in compliance
- 2012-10-01Combined Radium (-226 and -228)MCL, Averagemeasured 13.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2012-10-01Radium-228MCL, Averagemeasured 11.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2012-07-01Consumer Confidence RuleCCR Complete Failure to ReportBack in compliance
- 2012-07-01Combined UraniumMCL, Averagemeasured 33.00 UG/L · limit 30.00 UG/LBack in compliance
- 2012-07-01Combined Radium (-226 and -228)MCL, Averagemeasured 13.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2012-07-01Radium-228MCL, Averagemeasured 11.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2012-04-01Radium-228MCL, Averagemeasured 10.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2012-04-01Combined Radium (-226 and -228)MCL, Averagemeasured 12.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2012-04-01Combined UraniumMCL, Averagemeasured 34.00 UG/L · limit 30.00 UG/LBack in compliance
- 2012-01-01Radium-228MCL, Averagemeasured 11.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2012-01-01Combined Radium (-226 and -228)MCL, Averagemeasured 12.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2012-01-01Combined UraniumMCL, Averagemeasured 31.00 UG/L · limit 30.00 UG/LBack in compliance
- 2011-10-01Consumer Confidence RuleCCR Inadequate ReportingBack in compliance
- 2011-10-01Radium-228MCL, Averagemeasured 10.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2011-10-01Combined Radium (-226 and -228)MCL, Averagemeasured 12.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2011-10-01Combined UraniumMCL, Averagemeasured 33.00 UG/L · limit 30.00 UG/LBack in compliance
- 2011-07-01Radium-228MCL, Averagemeasured 10.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2011-07-01Combined Radium (-226 and -228)MCL, Averagemeasured 12.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2011-07-01Combined UraniumMCL, Averagemeasured 33.00 UG/L · limit 30.00 UG/LBack in compliance
- 2011-04-01Radium-228MCL, Single Samplemeasured 11.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2011-04-01Combined Radium (-226 and -228)MCL, Single Samplemeasured 12.00 PCI/L · limit 5.00 PCI/LBack in compliance
- 2006-10-01Lead and Copper RuleFollow-up Or Routine LCR Tap M/RBack in compliance
- 2006-07-01Consumer Confidence RuleCCR Complete Failure to ReportBack in compliance
- 2005-10-01Lead and Copper RuleFollow-up Or Routine LCR Tap M/RBack in compliance
- 2005-07-01Consumer Confidence RuleCCR Complete Failure to ReportBack in compliance
- 2004-07-01Consumer Confidence RuleCCR Complete Failure to ReportBack in compliance
- 2003-07-01Consumer Confidence RuleCCR Complete Failure to ReportBack in compliance
- 2002-07-01Consumer Confidence RuleCCR Complete Failure to ReportBack in compliance
System details
| Population served | 135 |
| Service connections | 3 |
| Water source | Groundwater |
| System type | Community Water System |
| Owner | Public/Private |
| Status | Active |
| City | Kingman |
| EPA ZIP on file | 86401 |
Areas served
- Kingman, Mohave County
Reading this record
Ranch Water Service Inc is a community water system that draws from groundwater and serves about 135 people in Kingman, Arizona. Everything above comes from the EPA's Safe Drinking Water Information System (SDWIS), where states report every violation by every public water system.
Four kinds of violation. Only one is a measurement of the water: over the limit means a test came back above a legal maximum (an MCL). A treatment lapse means a required protective step was not done, such as disinfection, filtration, fixing a defect an inspector found, or filing a lead-pipe inventory. A missed or late test means a required test was skipped or never reported. That is the most common kind, and the most misread: it does not mean the water was bad, and it does not mean the water was fine. Notices and reports covers public notices and the annual Consumer Confidence Report.
Status. “Back in compliance” means the state recorded a return to compliance. “Period ended” means the violation's compliance period is over but no return to compliance was ever filed, which is common in older records. EPA's federal copy lags state records by months, so call the utility for anything current.