Pocahontas Co Psd - Cheat Mountain Water
A missed test is not evidence of bad water. It also is not evidence of good water: for that period nobody checked.
On record since 2002: 46 violations. 13 over the limit · 15 missed or late tests · 18 notices or reports. Most recent began 2025-04-05.
For this year's test results, ask the utility for its annual Consumer Confidence Report. Every community system must publish one.
More violations on record than 70% of active water systems in West Virginia. Small systems with no staff chemist often rack up missed-test violations; big utilities rarely do.
The record, year by year
Across West Virginia, 68% of violations are missed or late tests and 1% are water over a limit.
How far over the limit
Lead & copper at the tap
Utilities sample taps in homes most likely to have lead pipes, and report the 90th-percentile result: 9 in 10 homes sampled came in at or below this number. Above the red line (the action level) the utility must act. The action level is not a safe level; EPA's health goal for lead is zero. EPA's file does not date these results, so they are shown highest first.
Lead, 90th percentile 12 results on file · action level 15 ppb
Open now (9)
- 2025-04-05Public NoticePN Violation for NPDWR ViolationOpen
- 2024-02-16Public Notice ×4PN Violation for NPDWR ViolationOpen
- 2022-12-03Public NoticePN Violation for NPDWR ViolationOpen
- 2022-07-16Public Notice ×3PN Violation for NPDWR ViolationOpen
Every violation on record
- 2025-04-05Public NoticePN Violation for NPDWR ViolationOpen
- 2025-04-01Trihalomethanes (TTHM)MCL, Averagemeasured 89.00 UG/L · limit 80.00 UG/LPeriod ended · no return to compliance on file
- 2025-01-10Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2025-01-01Trihalomethanes (TTHM)MCL, Averagemeasured 87.00 UG/L · limit 80.00 UG/LPeriod ended · no return to compliance on file
- 2024-10-01Trihalomethanes (TTHM)MCL, Averagemeasured 88.00 UG/L · limit 80.00 UG/LPeriod ended · no return to compliance on file
- 2024-02-16Public Notice ×4PN Violation for NPDWR ViolationOpen
- 2022-12-03Public NoticePN Violation for NPDWR ViolationOpen
- 2022-12-01Surface water filtration (IESWTR)Monitoring, Turbidity (Enhanced SWTR)Period ended · no return to compliance on file
- 2022-12-01Surface water treatment (SWTR)Monitoring of Treatment (SWTR-Filter)Period ended · no return to compliance on file
- 2022-10-01Carbon, TotalMonitoring and Reporting (DBP)Period ended · no return to compliance on file
- 2022-10-01ChlorineMonitoring and Reporting (DBP)Period ended · no return to compliance on file
- 2022-10-01Consumer Confidence RuleCCR Inadequate ReportingBack in compliance
- 2022-07-16Public Notice ×3PN Violation for NPDWR ViolationOpen
- 2022-07-01Total Haloacetic Acids (HAA5)MCL, Averagemeasured 62.00 UG/L · limit 60.00 UG/LPeriod ended · no return to compliance on file
- 2022-07-01Consumer Confidence RuleCCR Complete Failure to ReportBack in compliance
- 2021-05-01Surface water treatment (SWTR)Monitoring of Treatment (SWTR-Filter)Period ended · no return to compliance on file
- 2021-05-01Revised Total Coliform RuleMONPeriod ended · no return to compliance on file
- 2021-04-01ChlorineMonitoring and Reporting (DBP)Period ended · no return to compliance on file
- 2021-01-01NickelMonitoring, RegularPeriod ended · no return to compliance on file
- 2020-12-30Lead and Copper RuleLead Consumer NoticeBack in compliance
- 2020-01-16Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2019-10-01Trihalomethanes (TTHM)MCL, Averagemeasured 84.00 UG/L · limit 80.00 UG/LBack in compliance
- 2018-10-21Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2018-10-01Carbon, TotalMonitoring and Reporting (DBP)Back in compliance
- 2018-07-01Total Haloacetic Acids (HAA5)MCL, Averagemeasured 63.00 UG/L · limit 60.00 UG/LBack in compliance
Show the other 15 entries
- 2018-04-03Lead and Copper RuleLead Consumer NoticeBack in compliance
- 2018-04-01Surface water filtration (IESWTR)Monitoring, Turbidity (Enhanced SWTR)Back in compliance
- 2017-07-01Lead and Copper RuleWater Quality Parameter M/RBack in compliance
- 2017-07-01Trihalomethanes (TTHM)MCL, Averagemeasured 84.00 UG/L · limit 80.00 UG/LBack in compliance
- 2017-04-01Trihalomethanes (TTHM)MCL, Averagemeasured 88.00 UG/L · limit 80.00 UG/LPeriod ended · no return to compliance on file
- 2017-04-01Total Haloacetic Acids (HAA5)MCL, Averagemeasured 61.00 UG/L · limit 60.00 UG/LBack in compliance
- 2017-01-01Total Haloacetic Acids (HAA5)MCL, Averagemeasured 62.00 UG/L · limit 60.00 UG/LBack in compliance
- 2017-01-01Trihalomethanes (TTHM)MCL, Averagemeasured 88.00 UG/L · limit 80.00 UG/LPeriod ended · no return to compliance on file
- 2016-10-01Total Haloacetic Acids (HAA5)MCL, Averagemeasured 68.00 UG/L · limit 60.00 UG/LBack in compliance
- 2016-10-01Trihalomethanes (TTHM)MCL, Averagemeasured 87.00 UG/L · limit 80.00 UG/LPeriod ended · no return to compliance on file
- 2014-10-01Consumer Confidence RuleCCR Inadequate ReportingBack in compliance
- 2011-10-01Lead and Copper RuleFollow-up Or Routine LCR Tap M/RBack in compliance
- 2009-11-22Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2008-04-19Public Notice ×2PN Violation for NPDWR ViolationBack in compliance
- 2002-10-01Lead and Copper RuleFollow-up Or Routine LCR Tap M/RBack in compliance
System details
| Population served | 1,867 |
| Service connections | 210 |
| Water source | Surface Water |
| System type | Community Water System |
| Owner | Private |
| Status | Active |
| City | Durbin |
| EPA ZIP on file | 26264 |
Areas served
- Snowshoe Resort, Pocahontas County
Reading this record
Pocahontas Co Psd - Cheat Mountain Water is a community water system that draws from surface water and serves about 1,867 people in Durbin, West Virginia. Everything above comes from the EPA's Safe Drinking Water Information System (SDWIS), where states report every violation by every public water system.
Four kinds of violation. Only one is a measurement of the water: over the limit means a test came back above a legal maximum (an MCL). A treatment lapse means a required protective step was not done, such as disinfection, filtration, fixing a defect an inspector found, or filing a lead-pipe inventory. A missed or late test means a required test was skipped or never reported. That is the most common kind, and the most misread: it does not mean the water was bad, and it does not mean the water was fine. Notices and reports covers public notices and the annual Consumer Confidence Report.
Status. “Back in compliance” means the state recorded a return to compliance. “Period ended” means the violation's compliance period is over but no return to compliance was ever filed, which is common in older records. EPA's federal copy lags state records by months, so call the utility for anything current.