Transient Non-Community · PWSID PA1150659

Pasquales Pizza and Carryout

Serves 40 peopleGroundwaterOwner: PrivateCochranville, Pennsylvania
Nothing open right now.

On record since 2005: 33 violations. 5 over the limit · 1 treatment lapse · 11 missed or late tests · 16 notices or reports. Most recent began 2023-12-18.

For this year's test results, ask the utility for its annual Consumer Confidence Report. Every community system must publish one.

5Over the limit
1Treatment lapse
11Missed or late test
16Notice or report

More violations on record than 81% of active water systems in Pennsylvania. Small systems with no staff chemist often rack up missed-test violations; big utilities rarely do.

The record, year by year

2005 · Notice or report: 120052008 · Notice or report: 12009 · Notice or report: 12010 · Notice or report: 120102015 · Missed or late test: 32015 · Missed or late test: 32015 · Missed or late test: 32015 · Notice or report: 120152016 · Notice or report: 42016 · Notice or report: 42016 · Notice or report: 42016 · Notice or report: 42018 · Over the limit: 12019 · Treatment lapse: 12019 · Missed or late test: 32019 · Missed or late test: 32019 · Missed or late test: 32019 · Notice or report: 22019 · Notice or report: 22020 · Over the limit: 22020 · Over the limit: 22020 · Missed or late test: 22020 · Missed or late test: 22020 · Notice or report: 22020 · Notice or report: 220202022 · Missed or late test: 12023 · Over the limit: 22023 · Over the limit: 22023 · Missed or late test: 22023 · Missed or late test: 22023 · Notice or report: 32023 · Notice or report: 32023 · Notice or report: 32025
One square = one violation, by the year it began. Empty columns are years with nothing on EPA's record.
15% over the limit · 53% treatment lapse · 133% missed or late test · 1148% notice or report · 16

Across Pennsylvania, 71% of violations are missed or late tests and 2% are water over a limit.

Every violation on record

  1. 2023-12-18E. ColiMonitoring, Source Water (GWR)Back in compliance
  2. 2023-10-11Revised Total Coliform RuleRPTBack in compliance
  3. 2023-07-12Public NoticePN Violation for NPDWR ViolationBack in compliance
  4. 2023-04-12Public NoticePN Violation for NPDWR ViolationBack in compliance
  5. 2023-04-01NitrateMCL, Averagemeasured 12.25 MG/LBack in compliance
  6. 2023-02-01Revised Total Coliform RuleMONBack in compliance
  7. 2023-01-01NitrateMCL, Averagemeasured 31.54 MG/LBack in compliance
  8. 2022-10-01Revised Total Coliform RuleMONBack in compliance
  9. 2020-07-12Public NoticePN Violation for NPDWR ViolationBack in compliance
  10. 2020-04-12Public NoticePN Violation for NPDWR ViolationBack in compliance
  11. 2020-04-01NitrateMonitoring, Check/Repeat/ConfirmationBack in compliance
  12. 2020-04-01NitrateMCL, Single Samplemeasured 13.60 MG/LBack in compliance
  13. 2020-01-01NitrateMonitoring, Check/Repeat/ConfirmationBack in compliance
  14. 2020-01-01NitrateMCL, Single Samplemeasured 12.40 MG/LBack in compliance
  15. 2019-11-09Public NoticePN Violation for NPDWR ViolationBack in compliance
  16. 2019-09-29Revised Total Coliform RuleRPTBack in compliance
  17. 2019-09-29Revised Total Coliform RuleTTBack in compliance
  18. 2019-09-01Revised Total Coliform RuleMONBack in compliance
  19. 2019-07-01NitriteMonitoring, RegularBack in compliance
  20. 2019-07-01NitrateMonitoring, RegularBack in compliance
  21. 2018-01-01NitrateMCL, Averagemeasured 17.70 MG/LBack in compliance
  22. 2016-07-11Public Notice ×3PN Violation for NPDWR ViolationBack in compliance
  23. 2016-04-01Revised Total Coliform RuleOtherBack in compliance
  24. 2015-04-01NitriteMonitoring, RegularBack in compliance
  25. 2015-04-01NitrateMonitoring, RegularBack in compliance
Show the other 6 entries
  1. 2015-04-01Coliform (TCR)Monitoring, Routine Major (TCR)Back in compliance
  2. 2015-01-12Public NoticePN Violation for NPDWR ViolationBack in compliance
  3. 2010-10-12Public NoticePN Violation for NPDWR ViolationBack in compliance
  4. 2009-10-11Public NoticePN Violation for NPDWR ViolationBack in compliance
  5. 2008-10-12Public NoticePN Violation for NPDWR ViolationBack in compliance
  6. 2005-04-12Public NoticePN Violation for NPDWR ViolationBack in compliance

System details

Population served40
Service connections2
Water sourceGroundwater
System typeTransient Non-Community
OwnerPrivate
StatusActive
CityCochranville
EPA ZIP on file19330

Areas served

  • Chester County

Reading this record

Pasquales Pizza and Carryout is a transient non-community that draws from groundwater and serves about 40 people in Cochranville, Pennsylvania. Everything above comes from the EPA's Safe Drinking Water Information System (SDWIS), where states report every violation by every public water system.

Four kinds of violation. Only one is a measurement of the water: over the limit means a test came back above a legal maximum (an MCL). A treatment lapse means a required protective step was not done, such as disinfection, filtration, fixing a defect an inspector found, or filing a lead-pipe inventory. A missed or late test means a required test was skipped or never reported. That is the most common kind, and the most misread: it does not mean the water was bad, and it does not mean the water was fine. Notices and reports covers public notices and the annual Consumer Confidence Report.

Status. “Back in compliance” means the state recorded a return to compliance. “Period ended” means the violation's compliance period is over but no return to compliance was ever filed, which is common in older records. EPA's federal copy lags state records by months, so call the utility for anything current.