Oneida W&S Comm
PWSID: TN0000532
This system has no unresolved violations. The most recent violation on record was 2017-07-01.
This system has more violations on record than 89% of water systems in Tennessee.
Violation trend: 0.0 per year over the last 5 years, down from 1.2 per year in the previous 5.
System Details
| Population Served | 10,688 |
| Service Connections | 4,548 |
| Water Source | Surface Water |
| System Type | Community Water System |
| Owner | Local Government |
| Status | Active |
| City | Oneida |
| EPA ZIP on File | 37841 |
Areas Served
- Oneida, Scott County
Lead & Copper Testing
| Contaminant | Level | EPA Action Level | Status |
|---|---|---|---|
| Lead (90th percentile) | 0.0015 mg/L | 0.015 mg/L | Below Action Level |
| Lead (90th percentile) | 0.0014 mg/L | 0.015 mg/L | Below Action Level |
| Lead (90th percentile) | 0.0010 mg/L | 0.015 mg/L | Below Action Level |
| Lead (90th percentile) | 0.0010 mg/L | 0.015 mg/L | Below Action Level |
Violation History (17 total)
| Contaminant | Violation | Date | Health-Based | Status |
|---|---|---|---|---|
| 2456 | MCL Measured: 0.0610 MG/L (EPA limit: 0.060 mg/L) | 2017-07-01 | Yes | Returned to Compliance |
| 2456 | MCL Measured: 0.0640 MG/L (EPA limit: 0.060 mg/L) | 2017-04-01 | Yes | Returned to Compliance |
| 2456 | MCL Measured: 0.0652 MG/L (EPA limit: 0.060 mg/L) | 2017-01-01 | Yes | Returned to Compliance |
| 2950 | MCL Measured: 0.0809 MG/L | 2017-01-01 | Yes | Returned to Compliance |
| 2456 | MCL Measured: 0.0610 MG/L (EPA limit: 0.060 mg/L) | 2016-10-01 | Yes | Returned to Compliance |
| 2456 | MCL Measured: 0.0710 MG/L (EPA limit: 0.060 mg/L) | 2016-07-01 | Yes | Returned to Compliance |
| 2456 | MCL Measured: 0.0710 MG/L (EPA limit: 0.060 mg/L) | 2016-04-01 | Yes | Returned to Compliance |
| 2950 | MCL Measured: 0.0830 MG/L | 2016-04-01 | Yes | Returned to Compliance |
| 2456 | MCL Measured: 0.0680 MG/L (EPA limit: 0.060 mg/L) | 2016-01-01 | Yes | Returned to Compliance |
| 2950 | MCL Measured: 0.0850 MG/L | 2016-01-01 | Yes | Returned to Compliance |
| 2456 | MCL Measured: 0.0680 MG/L (EPA limit: 0.060 mg/L) | 2015-10-01 | Yes | Returned to Compliance |
| 2950 | MCL Measured: 0.0880 MG/L | 2015-10-01 | Yes | Returned to Compliance |
| 2456 | MCL Measured: 0.0660 MG/L (EPA limit: 0.060 mg/L) | 2015-07-01 | Yes | Returned to Compliance |
| 2950 | MCL Measured: 0.0860 MG/L | 2015-07-01 | Yes | Returned to Compliance |
| 2456 | MCL Measured: 0.0700 MG/L (EPA limit: 0.060 mg/L) | 2015-04-01 | Yes | Returned to Compliance |
| 2456 | MCL Measured: 0.0679 MG/L (EPA limit: 0.060 mg/L) | 2015-01-01 | Yes | Returned to Compliance |
| 2950 | MCL Measured: 0.0830 MG/L | 2015-01-01 | Yes | Returned to Compliance |
Understanding This Water System's Record
Oneida W&S Comm is a community water system water system that draws from surface water sources and serves a population of 10,688 in Oneida, Tennessee. This page shows its complete compliance history as reported to the EPA's Safe Drinking Water Information System (SDWIS), the federal database that tracks every public water system in the United States.
What Do These Violations Mean?
Health-based violations mean the system exceeded an EPA maximum contaminant level (MCL) or failed to provide required treatment. These indicate potential health risks from contaminants like lead, arsenic, bacteria, nitrates, or disinfection byproducts. Non-health-based violations involve monitoring, reporting, or procedural requirements — the system missed a testing deadline or failed to notify customers, but contaminant levels were not necessarily unsafe.
What Should You Do?
Your water utility is required to publish an annual Consumer Confidence Report (CCR) that details test results and any violations. If your system has active health-based violations, consider a certified water filter rated for the specific contaminants involved. The contaminant guides on this site explain health risks and filter options for common pollutants. For the most current results, contact your water utility directly — EPA data can lag weeks or months behind real-time testing.