Olive Hill Municipal Water Works
On record since 1995: 25 violations. 5 over the limit · 4 treatment lapses · 3 missed or late tests · 13 notices or reports. Most recent began 2022-11-01.
For this year's test results, ask the utility for its annual Consumer Confidence Report. Every community system must publish one.
More violations on record than 88% of active water systems in Kentucky. Small systems with no staff chemist often rack up missed-test violations; big utilities rarely do.
The record, year by year
Across Kentucky, 52% of violations are missed or late tests and 13% are water over a limit.
How far over the limit
Lead & copper at the tap
Utilities sample taps in homes most likely to have lead pipes, and report the 90th-percentile result: 9 in 10 homes sampled came in at or below this number. Above the red line (the action level) the utility must act. The action level is not a safe level; EPA's health goal for lead is zero. EPA's file does not date these results, so they are shown highest first.
Lead, 90th percentile 3 results on file · action level 15 ppb
Every violation on record
- 2022-11-01Revised Total Coliform RuleMONBack in compliance
- 2018-10-01Total Haloacetic Acids (HAA5)MCL, Averagemeasured 0.0670 MG/L · limit 0.0600 MG/LBack in compliance
- 2018-07-01Total Haloacetic Acids (HAA5)Failure Submit IDSE/Subpart V Plan RptBack in compliance
- 2018-04-01Carbon, TotalTreatment Technique Precursor RemovalBack in compliance
- 2018-04-01Total Haloacetic Acids (HAA5)MCL, Averagemeasured 0.0810 MG/L · limit 0.0600 MG/LBack in compliance
- 2018-01-04Public Notice ×2PN Violation for NPDWR ViolationBack in compliance
- 2018-01-01Carbon, TotalTreatment Technique Precursor RemovalBack in compliance
- 2018-01-01Total Haloacetic Acids (HAA5)MCL, Averagemeasured 0.0730 MG/L · limit 0.0600 MG/LBack in compliance
- 2017-10-01Carbon, TotalTreatment Technique Precursor RemovalBack in compliance
- 2017-10-01Total Haloacetic Acids (HAA5)MCL, Averagemeasured 0.0680 MG/L · limit 0.0600 MG/LBack in compliance
- 2017-07-01Carbon, TotalTreatment Technique Precursor RemovalBack in compliance
- 2017-07-01Total Haloacetic Acids (HAA5)MCL, Averagemeasured 0.0680 MG/L · limit 0.0600 MG/LBack in compliance
- 2011-08-17Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2011-07-01Consumer Confidence RuleCCR Complete Failure to ReportBack in compliance
- 2009-07-01Consumer Confidence RuleCCR Inadequate ReportingBack in compliance
- 2007-11-07Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2007-07-01Consumer Confidence RuleCCR Complete Failure to ReportBack in compliance
- 2005-07-01Consumer Confidence RuleCCR Inadequate ReportingBack in compliance
- 2005-07-01Consumer Confidence RuleCCR Complete Failure to ReportBack in compliance
- 2001-07-01Consumer Confidence RuleCCR Inadequate ReportingBack in compliance
- 2001-07-01Consumer Confidence RuleCCR Complete Failure to ReportBack in compliance
- 2000-07-01Consumer Confidence RuleCCR Complete Failure to ReportBack in compliance
- 2000-01-19Consumer Confidence RuleCCR Inadequate ReportingBack in compliance
- 1995-01-01Lead and Copper RuleFollow-up Or Routine LCR Tap M/RBack in compliance
System details
| Population served | 6,192 |
| Service connections | 2,395 |
| Water source | Surface Water |
| System type | Community Water System |
| Owner | Local Government |
| Status | Active |
| City | Olive Hill |
| EPA ZIP on file | 41164 |
Areas served
- Carter County
Reading this record
Olive Hill Municipal Water Works is a community water system that draws from surface water and serves about 6,192 people in Olive Hill, Kentucky. Everything above comes from the EPA's Safe Drinking Water Information System (SDWIS), where states report every violation by every public water system.
Four kinds of violation. Only one is a measurement of the water: over the limit means a test came back above a legal maximum (an MCL). A treatment lapse means a required protective step was not done, such as disinfection, filtration, fixing a defect an inspector found, or filing a lead-pipe inventory. A missed or late test means a required test was skipped or never reported. That is the most common kind, and the most misread: it does not mean the water was bad, and it does not mean the water was fine. Notices and reports covers public notices and the annual Consumer Confidence Report.
Status. “Back in compliance” means the state recorded a return to compliance. “Period ended” means the violation's compliance period is over but no return to compliance was ever filed, which is common in older records. EPA's federal copy lags state records by months, so call the utility for anything current.