Leisure Arms Complex

PWSID: NJ1704001

No active violations
This system has no unresolved violations. The most recent violation on record was 2019-11-11.

This system has more violations on record than 85% of water systems in New Jersey.

Violation trend: 0.0 per year over the last 5 years, down from 4.8 per year in the previous 5.

System Details

Population Served60
Service Connections31
Water SourceGroundwater
System TypeCommunity Water System
OwnerLocal Government
StatusActive
CityHancocks Bridge
EPA ZIP on File08038

Areas Served

  • Salem County

Lead & Copper Testing

ContaminantLevelEPA Action LevelStatus
Lead (90th percentile)0.0169 mg/L0.015 mg/LExceeds Action Level
Lead (90th percentile)0.0068 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0063 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0049 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0040 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0031 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0020 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0020 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0014 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0013 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level

Violation History (28 total)

ContaminantViolationDateHealth-BasedStatus
8000RPT2019-11-11Returned to Compliance
8000MON2019-10-01 MajorReturned to Compliance
5000MR2018-12-30Returned to Compliance
2378MR2017-01-01 MajorAcknowledged
2380MR2017-01-01 MajorAcknowledged
2955MR2017-01-01 MajorAcknowledged
2964MR2017-01-01 MajorAcknowledged
2968MR2017-01-01 MajorAcknowledged
2969MR2017-01-01 MajorAcknowledged
2976MR2017-01-01 MajorAcknowledged
2977MR2017-01-01 MajorAcknowledged
2979MR2017-01-01 MajorAcknowledged
2980MR2017-01-01 MajorAcknowledged
2981MR2017-01-01 MajorAcknowledged
2982MR2017-01-01 MajorAcknowledged
2983MR2017-01-01 MajorAcknowledged
2984MR2017-01-01 MajorAcknowledged
2985MR2017-01-01 MajorAcknowledged
2987MR2017-01-01 MajorAcknowledged
2989MR2017-01-01 MajorAcknowledged
2990MR2017-01-01 MajorAcknowledged
2991MR2017-01-01 MajorAcknowledged
2992MR2017-01-01 MajorAcknowledged
2996MR2017-01-01 MajorAcknowledged
3014MR2012-08-22 MajorReturned to Compliance
3014MR2012-06-28 MajorReturned to Compliance
3014MR2012-05-24 MajorReturned to Compliance
3014MR2011-06-24 MajorReturned to Compliance

Understanding This Water System's Record

Leisure Arms Complex is a community water system water system that draws from groundwater sources and serves a population of 60 in Hancocks Bridge, New Jersey. This page shows its complete compliance history as reported to the EPA's Safe Drinking Water Information System (SDWIS), the federal database that tracks every public water system in the United States.

What Do These Violations Mean?

Health-based violations mean the system exceeded an EPA maximum contaminant level (MCL) or failed to provide required treatment. These indicate potential health risks from contaminants like lead, arsenic, bacteria, nitrates, or disinfection byproducts. Non-health-based violations involve monitoring, reporting, or procedural requirements — the system missed a testing deadline or failed to notify customers, but contaminant levels were not necessarily unsafe.

What Should You Do?

Your water utility is required to publish an annual Consumer Confidence Report (CCR) that details test results and any violations. If your system has active health-based violations, consider a certified water filter rated for the specific contaminants involved. The contaminant guides on this site explain health risks and filter options for common pollutants. For the most current results, contact your water utility directly — EPA data can lag weeks or months behind real-time testing.