Kenston Middle School

PWSID: OH2844412

No active violations
This system has no unresolved violations. The most recent violation on record was 2020-04-01.

This system has more violations on record than 87% of water systems in Ohio.

Violation trend: 0.0 per year over the last 5 years, down from 2.4 per year in the previous 5.

System Details

Population Served515
Service Connections1
Water SourceGroundwater
System TypeNon-Transient Non-Community
OwnerPrivate
StatusActive
CityChagrin Falls
EPA ZIP on File44203
NoteSchool or Daycare

Lead & Copper Testing

ContaminantLevelEPA Action LevelStatus
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level

Violation History (12 total)

ContaminantViolationDateHealth-BasedStatus
2950MR2020-04-01 MajorReturned to Compliance
2456MR2020-04-01 MajorReturned to Compliance
2456MCL
Measured: 0.0630 MG/L (limit: 0.0600 MG/L)
2020-01-01YesAcknowledged
2456MCL
Measured: 0.0630 MG/L (limit: 0.0600 MG/L)
2020-01-01YesReturned to Compliance
2950MCL
Measured: 0.1280 MG/L (limit: 0.0800 MG/L)
2019-04-01YesReturned to Compliance
2456MCL
Measured: 0.0720 MG/L (limit: 0.0600 MG/L)
2019-04-01YesReturned to Compliance
2950MCL
Measured: 0.0900 MG/L (limit: 0.0800 MG/L)
2019-01-01YesReturned to Compliance
2456MCL
Measured: 0.0650 MG/L (limit: 0.0600 MG/L)
2019-01-01YesReturned to Compliance
2950MCL
Measured: 0.0890 MG/L (limit: 0.0800 MG/L)
2018-10-01YesReturned to Compliance
2456MCL
Measured: 0.0610 MG/L (limit: 0.0600 MG/L)
2018-10-01YesReturned to Compliance
2950MCL
Measured: 0.0890 MG/L (limit: 0.0800 MG/L)
2018-07-01YesReturned to Compliance
2456MCL
Measured: 0.0620 MG/L (limit: 0.0600 MG/L)
2018-07-01YesReturned to Compliance

Understanding This Water System's Record

Kenston Middle School is a non-transient non-community water system that draws from groundwater sources and serves a population of 515 in Chagrin Falls, Ohio. This page shows its complete compliance history as reported to the EPA's Safe Drinking Water Information System (SDWIS), the federal database that tracks every public water system in the United States.

What Do These Violations Mean?

Health-based violations mean the system exceeded an EPA maximum contaminant level (MCL) or failed to provide required treatment. These indicate potential health risks from contaminants like lead, arsenic, bacteria, nitrates, or disinfection byproducts. Non-health-based violations involve monitoring, reporting, or procedural requirements — the system missed a testing deadline or failed to notify customers, but contaminant levels were not necessarily unsafe.

What Should You Do?

Your water utility is required to publish an annual Consumer Confidence Report (CCR) that details test results and any violations. If your system has active health-based violations, consider a certified water filter rated for the specific contaminants involved. The contaminant guides on this site explain health risks and filter options for common pollutants. For the most current results, contact your water utility directly — EPA data can lag weeks or months behind real-time testing.