Jackman Utility District

PWSID: ME0090730

No active violations
This system has no unresolved violations. The most recent violation on record was 2023-07-01.

This system has more violations on record than 81% of water systems in Maine.

Violation trend: 4.4 per year over the last 5 years, up from 1.0 per year in the previous 5.

System Details

Population Served1,125
Service Connections450
Water SourceSurface Water
System TypeCommunity Water System
OwnerLocal Government
StatusActive
CityJackman
EPA ZIP on File04945

Areas Served

  • Jackman, Somerset County

Lead & Copper Testing

ContaminantLevelEPA Action LevelStatus
Lead (90th percentile)0.0320 mg/L0.015 mg/LExceeds Action Level
Lead (90th percentile)0.0220 mg/L0.015 mg/LExceeds Action Level
Lead (90th percentile)0.0210 mg/L0.015 mg/LExceeds Action Level
Lead (90th percentile)0.0210 mg/L0.015 mg/LExceeds Action Level
Lead (90th percentile)0.0180 mg/L0.015 mg/LExceeds Action Level
Lead (90th percentile)0.0140 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0122 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0098 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0088 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0086 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0067 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0056 mg/L0.015 mg/LBelow Action Level

Violation History (27 total)

ContaminantViolationDateHealth-BasedStatus
2950MCL
Measured: 0.0840 MG/L (limit: 0.0800 MG/L)
2023-07-01YesReturned to Compliance
2950MCL
Measured: 0.0840 MG/L (limit: 0.0800 MG/L)
2023-07-01YesAcknowledged
2950MCL
Measured: 0.0840 MG/L (limit: 0.0800 MG/L)
2023-07-01YesReturned to Compliance
2950MCL
Measured: 0.0840 MG/L (limit: 0.0800 MG/L)
2023-07-01YesReturned to Compliance
2950MCL
Measured: 0.0830 MG/L (limit: 0.0800 MG/L)
2023-04-01YesReturned to Compliance
2950MCL
Measured: 0.0830 MG/L (limit: 0.0800 MG/L)
2023-04-01YesAcknowledged
2950MCL
Measured: 0.0830 MG/L (limit: 0.0800 MG/L)
2023-04-01YesAcknowledged
2950MCL
Measured: 0.0830 MG/L (limit: 0.0800 MG/L)
2023-04-01YesReturned to Compliance
2950MCL
Measured: 0.0830 MG/L (limit: 0.0800 MG/L)
2023-04-01YesReturned to Compliance
2950MCL
Measured: 0.0840 MG/L (limit: 0.0800 MG/L)
2023-01-01YesReturned to Compliance
2950MCL
Measured: 0.0840 MG/L (limit: 0.0800 MG/L)
2023-01-01YesAcknowledged
2950MCL
Measured: 0.0840 MG/L (limit: 0.0800 MG/L)
2023-01-01YesAcknowledged
2950MCL
Measured: 0.0840 MG/L (limit: 0.0800 MG/L)
2023-01-01YesReturned to Compliance
2950MCL
Measured: 0.0840 MG/L (limit: 0.0800 MG/L)
2023-01-01YesReturned to Compliance
2456MCL
Measured: 0.0660 MG/L (limit: 0.0600 MG/L)
2023-01-01YesReturned to Compliance
2456MCL
Measured: 0.0660 MG/L (limit: 0.0600 MG/L)
2023-01-01YesAcknowledged
2456MCL
Measured: 0.0660 MG/L (limit: 0.0600 MG/L)
2023-01-01YesReturned to Compliance
2456MCL
Measured: 0.0660 MG/L (limit: 0.0600 MG/L)
2023-01-01YesReturned to Compliance
2950MCL
Measured: 0.0850 MG/L (limit: 0.0800 MG/L)
2022-10-01YesReturned to Compliance
2950MCL
Measured: 0.0850 MG/L (limit: 0.0800 MG/L)
2022-10-01YesAcknowledged
2950MCL
Measured: 0.0850 MG/L (limit: 0.0800 MG/L)
2022-10-01YesAcknowledged
2950MCL
Measured: 0.0850 MG/L (limit: 0.0800 MG/L)
2022-10-01YesReturned to Compliance
5000MR2020-09-29Returned to Compliance
5000MR2020-09-29Returned to Compliance
5000MR2020-09-29Returned to Compliance
5000MR2020-04-01Returned to Compliance
5000MR2020-04-01Returned to Compliance

Understanding This Water System's Record

Jackman Utility District is a community water system water system that draws from surface water sources and serves a population of 1,125 in Jackman, Maine. This page shows its complete compliance history as reported to the EPA's Safe Drinking Water Information System (SDWIS), the federal database that tracks every public water system in the United States.

What Do These Violations Mean?

Health-based violations mean the system exceeded an EPA maximum contaminant level (MCL) or failed to provide required treatment. These indicate potential health risks from contaminants like lead, arsenic, bacteria, nitrates, or disinfection byproducts. Non-health-based violations involve monitoring, reporting, or procedural requirements — the system missed a testing deadline or failed to notify customers, but contaminant levels were not necessarily unsafe.

What Should You Do?

Your water utility is required to publish an annual Consumer Confidence Report (CCR) that details test results and any violations. If your system has active health-based violations, consider a certified water filter rated for the specific contaminants involved. The contaminant guides on this site explain health risks and filter options for common pollutants. For the most current results, contact your water utility directly — EPA data can lag weeks or months behind real-time testing.