Hillside Village

PWSID: NJ2116002

No active violations
This system has no unresolved violations. The most recent violation on record was 2024-07-01.

This system has more violations on record than 79% of water systems in New Jersey.

Violation trend: 1.8 per year over the last 5 years, similar to 2.0 per year in the previous 5.

System Details

Population Served75
Service Connections28
Water SourceGroundwater
System TypeCommunity Water System
OwnerPrivate
StatusActive
CityNewton
EPA ZIP on File07860

Areas Served

  • Warren County

Lead & Copper Testing

ContaminantLevelEPA Action LevelStatus
Lead (90th percentile)0.0260 mg/L0.015 mg/LExceeds Action Level
Lead (90th percentile)0.0150 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0046 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0043 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0042 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0033 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0030 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0025 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0022 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0021 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0021 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0020 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0016 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0014 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0010 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0008 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0008 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0004 mg/L0.015 mg/LBelow Action Level

Violation History (21 total)

ContaminantViolationDateHealth-BasedStatus
5000MR2024-07-01Acknowledged
5000MR2024-07-01Acknowledged
5000MR2023-01-01Acknowledged
5000MR2023-01-01Acknowledged
5000MR2023-01-01Acknowledged
5000MR2023-01-01Acknowledged
1040MR2023-01-01 MajorReturned to Compliance
1040MR2023-01-01 MajorAcknowledged
1040MR2023-01-01 MajorAcknowledged
5000MR2020-07-01Returned to Compliance
5000MR2020-01-01Returned to Compliance
5000MR2019-07-01Returned to Compliance
5000MR2018-07-01Returned to Compliance
7000Other2017-07-01Returned to Compliance
4000MR2017-01-01 MajorReturned to Compliance
4006MR2017-01-01 MajorReturned to Compliance
4010MR2017-01-01 MajorReturned to Compliance
4020MR2017-01-01 MajorReturned to Compliance
4030MR2017-01-01 MajorReturned to Compliance
2950MR2015-01-01 MajorReturned to Compliance
2456MR2015-01-01 MajorReturned to Compliance

Understanding This Water System's Record

Hillside Village is a community water system water system that draws from groundwater sources and serves a population of 75 in Newton, New Jersey. This page shows its complete compliance history as reported to the EPA's Safe Drinking Water Information System (SDWIS), the federal database that tracks every public water system in the United States.

What Do These Violations Mean?

Health-based violations mean the system exceeded an EPA maximum contaminant level (MCL) or failed to provide required treatment. These indicate potential health risks from contaminants like lead, arsenic, bacteria, nitrates, or disinfection byproducts. Non-health-based violations involve monitoring, reporting, or procedural requirements — the system missed a testing deadline or failed to notify customers, but contaminant levels were not necessarily unsafe.

What Should You Do?

Your water utility is required to publish an annual Consumer Confidence Report (CCR) that details test results and any violations. If your system has active health-based violations, consider a certified water filter rated for the specific contaminants involved. The contaminant guides on this site explain health risks and filter options for common pollutants. For the most current results, contact your water utility directly — EPA data can lag weeks or months behind real-time testing.