Harford Technical High School

PWSID: MD1120035

No active violations
This system has no unresolved violations. The most recent violation on record was 2023-01-01.

This system has more violations on record than 92% of water systems in Maryland.

Violation trend: 2.2 per year over the last 5 years, up from 1.0 per year in the previous 5.

System Details

Population Served1,187
Service Connections1
Water SourceGroundwater
System TypeNon-Transient Non-Community
OwnerLocal Government
StatusActive
CityBel Air
EPA ZIP on File21015

Lead & Copper Testing

ContaminantLevelEPA Action LevelStatus
Copper (90th percentile)4.1800 mg/L1.300 mg/LExceeds Action Level
Copper (90th percentile)3.2000 mg/L1.300 mg/LExceeds Action Level
Copper (90th percentile)1.5000 mg/L1.300 mg/LExceeds Action Level
Lead (90th percentile)0.0160 mg/L0.015 mg/LExceeds Action Level
Lead (90th percentile)0.0130 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0110 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0110 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0100 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0050 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0030 mg/L0.015 mg/LBelow Action Level

Violation History (16 total)

ContaminantViolationDateHealth-BasedStatus
5000MR2023-01-01Returned to Compliance
5000MR2023-01-01Returned to Compliance
5000TT2022-04-01YesReturned to Compliance
5000TT2022-04-01YesReturned to Compliance
5000MR2022-04-01Returned to Compliance
5000MR2022-01-01Returned to Compliance
5000MR2022-01-01Returned to Compliance
5000MR2021-10-01Returned to Compliance
5000MR2021-10-01Returned to Compliance
5000TT2021-08-30YesReturned to Compliance
5000TT2021-08-30YesReturned to Compliance
5000MR2020-10-01Acknowledged
5000MR2020-10-01Returned to Compliance
5000MR2020-01-01Returned to Compliance
5000MR2019-07-01Returned to Compliance
8000MON2019-07-01 MajorReturned to Compliance

Understanding This Water System's Record

Harford Technical High School is a non-transient non-community water system that draws from groundwater sources and serves a population of 1,187 in Bel Air, Maryland. This page shows its complete compliance history as reported to the EPA's Safe Drinking Water Information System (SDWIS), the federal database that tracks every public water system in the United States.

What Do These Violations Mean?

Health-based violations mean the system exceeded an EPA maximum contaminant level (MCL) or failed to provide required treatment. These indicate potential health risks from contaminants like lead, arsenic, bacteria, nitrates, or disinfection byproducts. Non-health-based violations involve monitoring, reporting, or procedural requirements — the system missed a testing deadline or failed to notify customers, but contaminant levels were not necessarily unsafe.

What Should You Do?

Your water utility is required to publish an annual Consumer Confidence Report (CCR) that details test results and any violations. If your system has active health-based violations, consider a certified water filter rated for the specific contaminants involved. The contaminant guides on this site explain health risks and filter options for common pollutants. For the most current results, contact your water utility directly — EPA data can lag weeks or months behind real-time testing.