Eureka Wc
Open for: Lead and Copper Rule. EPA counts treatment-technique violations as health-based: a required protective step was not done. It is not a measurement of contamination.
On record since 2007: 111 violations. 61 over the limit · 3 treatment lapses · 29 missed or late tests · 18 notices or reports. Most recent began 2025-10-01.
For this year's test results, ask the utility for its annual Consumer Confidence Report. Every community system must publish one.
More violations on record than 97% of active water systems in Colorado. Small systems with no staff chemist often rack up missed-test violations; big utilities rarely do.
The record, year by year
Across Colorado, 74% of violations are missed or late tests and 6% are water over a limit.
How far over the limit
What you can do
- Lead: Run cold water for 30 seconds to 2 minutes before using it for drinking or cooking, especially after the water has been sitting for several hours. Use only cold water for cooking and baby formula. Consider a water filter certified to remove lead (look for NSF/ANSI Standard 53 certification). Have your water tested if you live in an older home.
Lead & copper at the tap
Utilities sample taps in homes most likely to have lead pipes, and report the 90th-percentile result: 9 in 10 homes sampled came in at or below this number. Above the red line (the action level) the utility must act. The action level is not a safe level; EPA's health goal for lead is zero. EPA's file does not date these results, so they are shown highest first.
Lead, 90th percentile 8 results on file · action level 15 ppb
Open now (2)
- 2025-10-01Lead and Copper RuleLead Consumer NoticeOpen
- 2025-04-01Lead and Copper RuleOCCT/SOWT Study/RecommendationOpen
Every violation on record
- 2025-10-01Lead and Copper RuleLead Consumer NoticeOpen
- 2025-10-01Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2025-08-11Public NoticePN Violation without NPDWR ViolationBack in compliance
- 2025-07-22Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2025-07-11Unknown contaminantRecord KeepingPeriod ended · no return to compliance on file
- 2025-07-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 16.00 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2025-07-01Combined Radium (-226 and -228)MCL, Averagemeasured 18.00 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2025-07-01Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2025-05-23Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2025-04-01Lead and Copper RuleOCCT/SOWT Study/RecommendationOpen
- 2025-04-01Combined UraniumMonitoring, RegularPeriod ended · no return to compliance on file
- 2025-04-01Gross Alpha, Excl. Radon and UMonitoring, RegularPeriod ended · no return to compliance on file
- 2025-04-01Combined Radium (-226 and -228)Monitoring, RegularPeriod ended · no return to compliance on file
- 2025-04-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 21.00 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2025-04-01Combined Radium (-226 and -228)MCL, Averagemeasured 20.00 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2025-04-01Lead and Copper RuleInitial, Follow-up, or Routine Source Water M/RBack in compliance
- 2025-04-01Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2025-01-31Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2025-01-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 24.90 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2025-01-01Combined Radium (-226 and -228)MCL, Averagemeasured 19.40 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2024-12-01Lead and Copper RuleLead Consumer NoticeBack in compliance
- 2024-12-01Lead and Copper RulePublic EducationBack in compliance
- 2024-10-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 27.33 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2024-10-01Combined Radium (-226 and -228)MCL, Averagemeasured 19.47 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2024-10-01Combined Radium (-226 and -228)Monitoring, RegularPeriod ended · no return to compliance on file
Show the other 86 entries
- 2024-10-01Combined UraniumMonitoring, RegularPeriod ended · no return to compliance on file
- 2024-10-01Gross Alpha, Excl. Radon and UMonitoring, RegularPeriod ended · no return to compliance on file
- 2024-10-01Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2024-07-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 27.90 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2024-07-01Combined Radium (-226 and -228)MCL, Averagemeasured 18.90 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2024-07-01Combined UraniumMonitoring, RegularBack in compliance
- 2024-07-01Gross Alpha, Excl. Radon and UMonitoring, RegularBack in compliance
- 2024-07-01Consumer Confidence RuleCCR Complete Failure to ReportBack in compliance
- 2024-04-01Combined Radium (-226 and -228)MCL, Averagemeasured 18.15 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2024-04-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 24.40 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2024-03-07Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2024-02-01DBP Stage 1Treatment Technique No Certif. OperatorBack in compliance
- 2024-01-01NitrateMonitoring, RegularPeriod ended · no return to compliance on file
- 2024-01-01Combined Radium (-226 and -228)MCL, Averagemeasured 17.90 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2024-01-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 26.90 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2024-01-01Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2023-10-01Combined UraniumMonitoring, RegularBack in compliance
- 2023-10-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2023-10-01Gross Alpha, Excl. Radon and UMonitoring, RegularBack in compliance
- 2023-10-01Combined Radium (-226 and -228)MCL, Averagemeasured 18.10 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2023-10-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 29.60 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2023-10-01Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2023-07-01Combined UraniumMonitoring, RegularBack in compliance
- 2023-07-01Combined Radium (-226 and -228)Monitoring, RegularBack in compliance
- 2023-07-01Gross Alpha, Excl. Radon and UMonitoring, RegularBack in compliance
- 2023-07-01Combined Radium (-226 and -228)MCL, Averagemeasured 17.83 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2023-07-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 28.27 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2023-04-01Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2023-04-01Combined Radium (-226 and -228)MCL, Averagemeasured 18.10 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2023-04-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 28.60 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2023-01-01Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2023-01-01Combined Radium (-226 and -228)MCL, Averagemeasured 18.10 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2023-01-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 28.60 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2022-10-01Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2022-10-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 21.00 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2022-10-01Combined Radium (-226 and -228)MCL, Averagemeasured 18.00 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2022-07-01Public NoticePN Violation for NPDWR ViolationBack in compliance
- 2022-07-01Combined Radium (-226 and -228)MCL, Averagemeasured 19.00 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2022-04-01Combined Radium (-226 and -228)MCL, Averagemeasured 20.00 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2022-01-01Combined Radium (-226 and -228)MCL, Averagemeasured 21.00 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2021-10-01Combined Radium (-226 and -228)MCL, Averagemeasured 22.29 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2021-07-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 18.00 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2021-07-01Combined Radium (-226 and -228)MCL, Averagemeasured 22.00 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2021-04-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 22.00 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2021-04-01Combined Radium (-226 and -228)MCL, Averagemeasured 21.00 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2021-01-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 24.25 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2021-01-01Combined Radium (-226 and -228)MCL, Averagemeasured 20.70 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2020-10-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 28.50 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2020-10-01Combined Radium (-226 and -228)MCL, Averagemeasured 21.20 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2020-07-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 29.00 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2020-07-01Combined Radium (-226 and -228)MCL, Averagemeasured 21.50 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2020-04-01Combined Radium (-226 and -228)MCL, Averagemeasured 21.80 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2020-04-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 29.50 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2020-01-01Combined Radium (-226 and -228)MCL, Averagemeasured 21.55 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2020-01-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 27.25 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2019-10-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 25.00 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2019-10-01Combined Radium (-226 and -228)MCL, Averagemeasured 21.30 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2019-07-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 27.00 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2019-07-01Combined Radium (-226 and -228)MCL, Averagemeasured 21.15 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2019-04-01Combined Radium (-226 and -228)MCL, Averagemeasured 21.00 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2019-04-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 29.00 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2019-01-01Combined Radium (-226 and -228)MCL, Averagemeasured 20.75 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2019-01-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 29.25 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2018-10-01Combined Radium (-226 and -228)MCL, Averagemeasured 20.50 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2018-10-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 29.50 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2018-07-01Combined Radium (-226 and -228)MCL, Averagemeasured 20.67 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2018-07-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 27.67 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2018-04-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 20.67 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2018-04-01Combined Radium (-226 and -228)MCL, Averagemeasured 20.00 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2018-01-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 19.00 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2018-01-01Combined Radium (-226 and -228)MCL, Averagemeasured 19.50 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2017-01-01Combined Radium (-226 and -228)MCL, Averagemeasured 18.00 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2016-01-01Combined Radium (-226 and -228)MCL, Averagemeasured 17.50 PCI/L · limit 5.00 PCI/LPeriod ended · no return to compliance on file
- 2016-01-01Gross Alpha, Excl. Radon and UMCL, Averagemeasured 18.00 PCI/L · limit 15.00 PCI/LPeriod ended · no return to compliance on file
- 2011-01-01SeleniumMonitoring, RegularBack in compliance
- 2011-01-01Thallium, TotalMonitoring, RegularBack in compliance
- 2011-01-01Beryllium, TotalMonitoring, RegularBack in compliance
- 2011-01-01Antimony, TotalMonitoring, RegularBack in compliance
- 2011-01-01SodiumMonitoring, RegularBack in compliance
- 2011-01-01NickelMonitoring, RegularBack in compliance
- 2011-01-01MercuryMonitoring, RegularBack in compliance
- 2011-01-01ChromiumMonitoring, RegularBack in compliance
- 2011-01-01CadmiumMonitoring, RegularBack in compliance
- 2011-01-01BariumMonitoring, RegularBack in compliance
- 2011-01-01ArsenicMonitoring, RegularBack in compliance
- 2007-07-01Consumer Confidence RuleCCR Complete Failure to ReportBack in compliance
System details
| Population served | 498 |
| Service connections | 147 |
| Water source | Groundwater |
| System type | Community Water System |
| Owner | Private |
| Status | Active |
| City | Rocky Ford |
| EPA ZIP on file | 81067 |
Areas served
- Otero County
Reading this record
Eureka Wc is a community water system that draws from groundwater and serves about 498 people in Rocky Ford, Colorado. Everything above comes from the EPA's Safe Drinking Water Information System (SDWIS), where states report every violation by every public water system.
Four kinds of violation. Only one is a measurement of the water: over the limit means a test came back above a legal maximum (an MCL). A treatment lapse means a required protective step was not done, such as disinfection, filtration, fixing a defect an inspector found, or filing a lead-pipe inventory. A missed or late test means a required test was skipped or never reported. That is the most common kind, and the most misread: it does not mean the water was bad, and it does not mean the water was fine. Notices and reports covers public notices and the annual Consumer Confidence Report.
Status. “Back in compliance” means the state recorded a return to compliance. “Period ended” means the violation's compliance period is over but no return to compliance was ever filed, which is common in older records. EPA's federal copy lags state records by months, so call the utility for anything current.