Cs El Prado Water Company

PWSID: AZ0414442

1 active violation (non-health-based)
This system has unresolved violations related to monitoring, reporting, or procedural requirements, but none involve contaminant levels exceeding EPA health limits.

This system has more violations on record than 98% of water systems in Missouri.

Violation trend: 14.0 per year over the last 5 years, similar to 14.4 per year in the previous 5.

System Details

Population Served404
Service Connections158
Water SourceGroundwater
System TypeCommunity Water System
OwnerPrivate
StatusActive
CityDes Peres
EPA ZIP on File63131

Areas Served

  • Yuma, Yuma County

Lead & Copper Testing

ContaminantLevelEPA Action LevelStatus
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level

1 Active Violations

ContaminantViolationDateHealth-BasedStatus
5000MR2024-10-01Open

Violation History (202 total)

ContaminantViolationDateHealth-BasedStatus
7500Other2025-08-17Returned to Compliance
1005MCL
Measured: 0.0250 MG/L (limit: 0.0100 MG/L)
2025-07-01YesAcknowledged
7500Other2025-06-07Returned to Compliance
1005MCL
Measured: 0.0240 MG/L (limit: 0.0100 MG/L)
2025-04-01YesAcknowledged
1005MCL
Measured: 0.0240 MG/L (limit: 0.0100 MG/L)
2025-04-01YesAcknowledged
1005MR2025-01-01 MajorAcknowledged
1005MR2025-01-01 MajorReturned to Compliance
1005MCL
Measured: 0.0210 MG/L (limit: 0.0100 MG/L)
2025-01-01YesAcknowledged
1005MCL
Measured: 0.0210 MG/L (limit: 0.0100 MG/L)
2025-01-01YesAcknowledged
1005MCL
Measured: 0.0210 MG/L (limit: 0.0100 MG/L)
2025-01-01YesAcknowledged
1005MCL
Measured: 0.0210 MG/L (limit: 0.0100 MG/L)
2024-10-01YesAcknowledged
1005MCL
Measured: 0.0140 MG/L (limit: 0.0100 MG/L)
2024-07-01YesAcknowledged
1005MCL
Measured: 0.0140 MG/L (limit: 0.0100 MG/L)
2024-07-01YesAcknowledged
1005MCL
Measured: 0.0120 MG/L (limit: 0.0100 MG/L)
2024-04-01YesAcknowledged
1005MCL
Measured: 0.0120 MG/L (limit: 0.0100 MG/L)
2024-04-01YesAcknowledged
1005MCL
Measured: 0.0120 MG/L (limit: 0.0100 MG/L)
2024-04-01YesAcknowledged
1005MR2024-04-01 MajorReturned to Compliance
1005MR2024-04-01 MajorAcknowledged
1005MR2024-04-01 MajorReturned to Compliance
1005MR2024-04-01 MajorReturned to Compliance
8000MCL2024-03-01YesReturned to Compliance
8000MCL2024-03-01YesAcknowledged
8000MCL2024-03-01YesReturned to Compliance
5000MR2024-01-01Returned to Compliance
5000MR2024-01-01Returned to Compliance
8000MON2024-01-01 MajorReturned to Compliance
8000MON2024-01-01 MajorReturned to Compliance
8000MON2024-01-01 MajorReturned to Compliance
5000MR2022-10-13Returned to Compliance
5000MR2022-10-13Returned to Compliance
1005MCL
Measured: 0.0110 MG/L (limit: 0.0100 MG/L)
2022-10-01YesReturned to Compliance
1005MCL
Measured: 0.0110 MG/L (limit: 0.0100 MG/L)
2022-10-01YesAcknowledged
1005MCL
Measured: 0.0110 MG/L (limit: 0.0100 MG/L)
2022-10-01YesReturned to Compliance
1005MCL
Measured: 0.0110 MG/L (limit: 0.0100 MG/L)
2022-10-01YesReturned to Compliance
1005MCL
Measured: 0.0130 MG/L (limit: 0.0100 MG/L)
2022-07-01YesReturned to Compliance
1005MCL
Measured: 0.0130 MG/L (limit: 0.0100 MG/L)
2022-07-01YesAcknowledged
1005MCL
Measured: 0.0130 MG/L (limit: 0.0100 MG/L)
2022-07-01YesReturned to Compliance
1005MCL
Measured: 0.0130 MG/L (limit: 0.0100 MG/L)
2022-07-01YesReturned to Compliance
1005MCL
Measured: 0.0150 MG/L (limit: 0.0100 MG/L)
2022-04-01YesReturned to Compliance
1005MCL
Measured: 0.0150 MG/L (limit: 0.0100 MG/L)
2022-04-01YesAcknowledged
1005MCL
Measured: 0.0150 MG/L (limit: 0.0100 MG/L)
2022-04-01YesReturned to Compliance
0700TT2022-03-10YesReturned to Compliance
0700TT2022-03-10YesReturned to Compliance
0700TT2022-03-10YesReturned to Compliance
0700TT2022-03-10YesReturned to Compliance
0700TT2022-03-10YesReturned to Compliance
0700TT2022-03-10YesReturned to Compliance
0700TT2022-03-02YesReturned to Compliance
0700TT2022-03-02YesReturned to Compliance
7500Other2022-02-14Returned to Compliance

Showing 50 of 201 historical violations.

Understanding This Water System's Record

Cs El Prado Water Company is a community water system water system that draws from groundwater sources and serves a population of 404 in Des Peres, Missouri. This page shows its complete compliance history as reported to the EPA's Safe Drinking Water Information System (SDWIS), the federal database that tracks every public water system in the United States.

What Do These Violations Mean?

Health-based violations mean the system exceeded an EPA maximum contaminant level (MCL) or failed to provide required treatment. These indicate potential health risks from contaminants like lead, arsenic, bacteria, nitrates, or disinfection byproducts. Non-health-based violations involve monitoring, reporting, or procedural requirements — the system missed a testing deadline or failed to notify customers, but contaminant levels were not necessarily unsafe.

What Should You Do?

Your water utility is required to publish an annual Consumer Confidence Report (CCR) that details test results and any violations. If your system has active health-based violations, consider a certified water filter rated for the specific contaminants involved. The contaminant guides on this site explain health risks and filter options for common pollutants. For the most current results, contact your water utility directly — EPA data can lag weeks or months behind real-time testing.