Cne - New London Turnpike Entry Point

PWSID: RI2980453

No active violations
This system has no unresolved violations. The most recent violation on record was 2024-10-01.

This system has more violations on record than 88% of water systems in Rhode Island.

Violation trend: 4.0 per year over the last 5 years, up from 1.8 per year in the previous 5.

System Details

Population Served9,999
Service Connections97
Water SourceGroundwater Purchased
System TypeCommunity Water System
OwnerPrivate
StatusActive
CityWarwick
EPA ZIP on File02886

Areas Served

  • Coventry, Kent County

Lead & Copper Testing

ContaminantLevelEPA Action LevelStatus
Lead (90th percentile)0.0015 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0014 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0012 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0008 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level
Lead (90th percentile)0.0000 mg/L0.015 mg/LBelow Action Level

Violation History (31 total)

ContaminantViolationDateHealth-BasedStatus
2950MR2024-10-01 MajorAcknowledged
2950MR2024-10-01 MajorReturned to Compliance
2456MR2024-10-01 MajorAcknowledged
2456MR2024-10-01 MajorReturned to Compliance
2950MR2024-04-01 MajorReturned to Compliance
2950MR2024-04-01 MajorAcknowledged
2950MR2024-04-01 MajorReturned to Compliance
2456MR2024-04-01 MajorReturned to Compliance
2456MR2024-04-01 MajorAcknowledged
2456MR2024-04-01 MajorReturned to Compliance
2950MR2024-01-01 MajorReturned to Compliance
2950MR2024-01-01 MajorAcknowledged
2456MR2024-01-01 MajorReturned to Compliance
2456MR2024-01-01 MajorAcknowledged
7000Other2022-07-01Returned to Compliance
7000Other2022-07-01Returned to Compliance
2950MR2022-01-01 MajorReturned to Compliance
2950MR2022-01-01 MajorReturned to Compliance
2456MR2022-01-01 MajorReturned to Compliance
2456MR2022-01-01 MajorReturned to Compliance
7000Other2018-07-01Returned to Compliance
2950MR2018-04-01Returned to Compliance
7500Other2018-01-20Returned to Compliance
2950MCL
Measured: 0.0810 MG/L (limit: 0.0800 MG/L)
2018-01-01YesReturned to Compliance
7500Other2017-12-31Returned to Compliance
0700Other2017-12-22Returned to Compliance
8000MCL2017-12-01YesAcknowledged
2950MCL
Measured: 81.00 UG/L (limit: 80.00 UG/L)
2017-10-01YesReturned to Compliance
7000Other2016-07-01Returned to Compliance
7000Other2015-12-10Returned to Compliance
7000Other2015-07-01Returned to Compliance

Understanding This Water System's Record

Cne - New London Turnpike Entry Point is a community water system water system that draws from groundwater purchased sources and serves a population of 9,999 in Warwick, Rhode Island. This page shows its complete compliance history as reported to the EPA's Safe Drinking Water Information System (SDWIS), the federal database that tracks every public water system in the United States.

What Do These Violations Mean?

Health-based violations mean the system exceeded an EPA maximum contaminant level (MCL) or failed to provide required treatment. These indicate potential health risks from contaminants like lead, arsenic, bacteria, nitrates, or disinfection byproducts. Non-health-based violations involve monitoring, reporting, or procedural requirements — the system missed a testing deadline or failed to notify customers, but contaminant levels were not necessarily unsafe.

What Should You Do?

Your water utility is required to publish an annual Consumer Confidence Report (CCR) that details test results and any violations. If your system has active health-based violations, consider a certified water filter rated for the specific contaminants involved. The contaminant guides on this site explain health risks and filter options for common pollutants. For the most current results, contact your water utility directly — EPA data can lag weeks or months behind real-time testing.